Connecting the Sensor

Once BMS setup is complete:

  1. Ensure anb_utils is open in the Command Line Prompt window
  2. Ensure the BMS is in the Sensor Detection Sequence, indicated by double beeps. Send a reboot command to get into the Sensor Detection Sequence
  3. Connect the sensor to the BMS, and the sensor will beep to indicate it has been powered
  4. The BMS will stop beeping, and the splash screen will be displayed
  5. Data will begin to stream in accordance to .
note

Sensor settings must be configured before connecting to the BMS. They cannot be changed whilst connected to the BMS.

Testing the system prior to deployment

Place the sensor in a container of water. Issue the REBOOT command to the BMS via the command line prompt and the BMS will begin sensor deployment following the pre-set measurement routine.

Sensor data is output at your configured scan interval in the command line prompt window.

$ANB,OA39,2026:06:09:11:25:16,7.59,22.66,36.24,55.23,0,0,0,55,0000220,22.0